Fault32 - For Windows XP / Vista & 7.0

Calculation of Network Currents and Voltages under Fault conditions
A powerful easy to use tool for determining fault currents magnitudes, the distribution of fault currents in a network, and corresponding network voltages.
Calculates the standard balanced and unbalanced faults, with the option of including the effect of fault impedance on the fault currents.
Used by engineers and technical personnel responsible for planning, design, operation and protection of electric power networks.

Use Fault32 for analysing the following types of power system faults in both radial and fully meshed networks:
• Line to Earth
• Line to Line
• Line to Line and Ground
• Three Phase
Faults may be applied to any node on the system or anywhere (from 5% to 95% of the length) along any line in the network.
Optionally, the effect impedance in the fault can be included in the calculation either for conformity with AS3851/IEC 909, or to take into account voltages known to differ appreciably from the nominal voltage.
Fault32 is used to:
• Assess fault currents for the design of protective grounding systems
• Determine ratings required for plant and equipment (Switchgear etc)
• Design protection systems
• Determine protection device settings
• Review protection system performance after faults
Features
Fault32 takes full account of phase shifts through transformers and caters for the entry of data on 3-winding transformers from nameplate details. Data files can be entirely created within the program, or externally. Data used may reside in external databases, or GIS systems, in some circumstances.
Versions Available
Fault32 is available in two versions. The 200-node capacity version is suited to smaller networks, such as mines and industrial plants and for consultants whose works is generally limited to such networks. The 3000-node version meets the needs of utilities and consultants whose projects may include design of utility networks or very large industrial plants. A special Education edition is available for Universities and similar training institutions.

Ideal Training Tool
Fault32 is available is ideal for training design, protection & operating personnel,technicians and undergraduates
who need to understand how a power network performs under fault conditions.

System Requirements
• IBM compatible computer with Windows XP/Vista or 7.0
• At least the minimum memory required by the operating system
• Approximately 16mb Hard disk space
• SVGA monitor
• Printer or plotter (Colour preferred)

Features
• Node/Bus or line faults can be applied
• Line faults can be located from 5% to 95% along the length of the line
• Option to set breaker open condition with line faults
• Optional fault impedances
• User selected option to work with Feeder and Grounding impedance in ohms per unit
• Optional automatic conversion of existing data when Feeder & Grounding Impedance option is changed from ohm to per unit, or vice versa. This allows data to be entered in either units as required.
• Extensive support for data entry and calculations conforming to requirements of Australian standard AS3851 "The calculation of short circuit currents in three phase a.c. systems
• Calculations validated against standard text book examples and AS3851. Files provided for user verification

Features Cont'd
• Handles transformer phase shifts for various start and delta winding combinations
• 3-winding transformers directly supported with data entry based on "Nameplate details"
• Results available in Phase or Sequence values(i.e Phase A, B & C or Positive, Negative & Zero sequence)
• Fault currents reported in kA, MVA and per unit of system base
• Quick and easy "switching" (i.e setting status) of network component to be IN or OUT of service
• All data files needed can be created and edited within Fault32 or can be sourced externally - for example, from Datashares' "ViewNet" (Database of network Impedance and Network connectivity) software or, in some circumstances, data can be accessed from external databases, GIS systems etc. (Details on accessing external data sources available on request)
• Feeder to store and retrieve common line/cable impedance data. Data stored in ohm/unit length and automatically converted to user selected units for Line/Feeder data, i.e ohms per unit
• Transformer database to store and retrieve impedance data. Any transformers details available in the Transformer details available in the Transformer data editor in Fault32 can be directly added to the transformer database
• Database categories can be defined to group entries and simplify descriptions and selection
• Copy and Paste to duplicate any network component (ie Node/Bus, Source, Transformer, Line/Feeder)
• Tool-bars for quick access to all main functions in the program
• Context (Right mouse button) menus when in data editors for easy access to editor functions
• Extensible data validity checking
• Data is compatible with Datashares' PowSys32 and Relcord32
• Network wide reports, or reports based on area & zone identification, as well as the Bus/Node list (a user selected list of nodes)
• Graphical and tabular presentation of results
• Reports can be directed to Screen, Printer or File
• Reports to file are ASCII text files able to be imported into spreadsheets for further processing, graphing, word processors for inclusion in report documents

Program Capacity
Edition 200 Node 3000 Node
Bus/Node 200 3000
Sources 50 600
Transformers 150 1500
Lines / Feeders 200 3000
Larger systems sizes may be available, by arrangement
 
Power Consultants Ltd NZ 64 9 4440663; Power Consultants PTY Ltd. Aus. 61 2 99296019; email: Info@pwrcon.co.nz - website: www.pwrcon.co.nz
[Print] [Top] [Request More Information] [Home] [Customer Links]